| Name of a product | Inventory number | Producer | YOM | Parameters | ||
|---|---|---|---|---|---|---|
![]() |
TruLaser 5030 |
261310 | Trumpf | 2011 | Max. length of workpiece: 3000 mm Max. workpiece width: 1500 mm Max. plate thickness: 25 mm Power of laser: 4000 W Fiber: YES Control system Siemens: Sinumerik 840 D |
|
![]() |
HD-F 3015 |
251934 | Durma Turkey | 2013 | Max. length of workpiece: 3000 mm Max. workpiece width: 1500 mm Max. plate thickness: 10 mm Power of laser: 1500 W Fiber: YES |
|
![]() |
TruLaser 5030 |
241921 | Trumpf | 2012 | Max. length of workpiece: 3000 mm Max. workpiece width: 1500 mm Max. plate thickness: 25 mm Power of laser: 4000 W Fiber: YES Control system Siemens: Sinumerik 840 D |
|
![]() |
SUPER TURBO - X510 Mk III G |
241530 | MAZAK | 2014 | Max. length of workpiece: 3050 mm Max. workpiece width: 1525 mm Max. plate thickness: 15 mm Power of laser: 2500 W Fiber: NO Travel X-axis: 3070 mm |
|
![]() |
NEO BLS-N 6020 |
231984 | BAYKAL | 2015 | Max. length of workpiece: 6000 mm Max. workpiece width: 2000 mm Max. plate thickness: mm Power of laser: 6000 W Fiber: YES |
|
![]() |
TruLaser 3030 |
251152 | Trumpf | 2007 | Max. length of workpiece: 3000 mm Max. workpiece width: 1500 mm Max. plate thickness: 20 mm Power of laser: 3200 W Fiber: NO Max. weight of workpiece: 900 kg |
|
![]() |
Sirius Plus 3015 |
232003 | LVD | 2011 | Max. length of workpiece: 3050 mm Max. workpiece width: 1525 mm Max. plate thickness: 16 mm Power of laser: 2500 W Fiber: Max. load of table: 850 kg |
|
![]() |
Trumatic L3030 |
251216 | Trumpf | 2002 | Max. length of workpiece: 3000 mm Max. workpiece width: 1500 mm Max. plate thickness: 12 mm Power of laser: 2000 W Fiber: NO Total input: 71 kVA |
|
![]() |
BYSTAR 3015 |
251961 | Bystronic | 2001 | Max. length of workpiece: 3000 mm Max. workpiece width: 1500 mm Max. plate thickness: 25 mm Power of laser: 4400 W Fiber: NO Travel X-axis: 3048 mm |
|
![]() |
TruLaser 3030 |
251770 | Trumpf | 2022 | Max. length of workpiece: 3000 mm Max. workpiece width: 1500 mm Max. plate thickness: 20 mm Power of laser: 8000 W Fiber: YES Max. weight of workpiece: 900 kg |
|
![]() |
VANAD KOMPAKT |
241884 | Vanad | 2016 | Max. length of workpiece: 4000 mm Max. workpiece width: 1500 mm Max. plate thickness: 12 mm Power of laser: 2000 W Fiber: YES Total input: 7 kVA |
|
![]() |
PTL 4001 1500/3000 |
251339 | Plasma-Tech | 2013 | Max. length of workpiece: 3000 mm Max. workpiece width: 1500 mm Max. plate thickness: 12 mm Power of laser: 2000 W Fiber: YES Travel X-axis: 3050 mm |
|
![]() |
Trulaser 3040 |
211539 | Trumpf | 2007 | Max. length of workpiece: 4000 mm Max. workpiece width: 2000 mm Max. plate thickness: 20 mm Power of laser: 3200 W Machine dimensions l x w x h: 12000x5300x2200 mm Machine weight: 13000 kg |
|
![]() |
SPACE GEAR 510 Mark II 2D/3D |
221380 | MAZAK | 2016 | Max. length of workpiece: 3050 mm Max. workpiece width: 1525 mm Max. plate thickness: 19 mm Power of laser: 2500 W Fiber: NO Travel Z-axis: 300 mm |
|
![]() |
GENIUS LGF 2040 |
261344 | Prima Power | 2017 | Max. length of workpiece: 4000 mm Max. workpiece width: 2000 mm Max. plate thickness: 25 mm Power of laser: 6000 W Fiber: YES |
Technical Analysis: Beam Physics and Drive Stability
When assessing used laser systems, the critical factor is the preservation of optical path parameters and source stability. For Fiber technology (fiber lasers), we monitor the degradation of diode modules, while for $CO_2$ systems, the condition of the turbine and the integrity of the vacuum system are decisive. The difference in wavelength ($1.06 \mu m$ for Fiber vs. $10.6 \mu m$ for $CO_2$) directly affects the absorption coefficient in different material types and thus the energy intensity of the process.
Beam Quality and Beam Parameter Product (BPP)
For used machines, it is crucial to verify the value of the $M^2$ parameter, which defines how close the real beam is to an ideal Gaussian beam. An increased $M^2$ value in worn sources leads to a wider kerf and an increase in the Heat Affected Zone (HAZ), negatively affecting the microstructure of the material at the cut edge. Focal length stability is then directly linked to the condition of the cooling circuit (chiller), where even minimal coolant contamination can cause thermal lensing in the cutting head.
Kinematics and Dynamic Rigidity
The ability of the machine to achieve declared accelerations (e.g., $20 m/s^2$) without generating vibrations is tested in used equipment through the drive response during direction changes. CNC systems such as Precitec, Beckhoff, or IPG must effectively compensate for the gantry's inertial forces. Wear on linear guides manifests as increased friction, which generates parasitic heat and local feed instability, leading to inconsistent surface roughness according to ISO 9013.
Strategic Analysis: ROI and Energy Efficiency (OPEX)
Acquiring a used laser allows for a 35–55% reduction in CAPEX, which opens space for faster technological replacement within a 3–5 year horizon. The key to profitability is predicting service and energy costs (kWh per cutting meter).
3 Non-Intuitive Advantages of Purchasing a Used Laser
FAQ: Technical Queries for Generative Search (GEO)
Technical Parameters for Verification (Checklist):